Solenoid valve malfunction a awm dan tur .

Aug 04, 2020

Message pakhat dah la .

1. Electronic valve a leak em tih enfiah rawh. Air leakage hian air pressure tling lo a thlen ang a, forced valve hawn a harsa hle ang. A tlangpuiin, sealing gasket a chhiat vang emaw, slide valve a hloh nasat vang emaw a ni a, chu chuan cavity-ah boruak a leak chhuak thin.

2. Solenoid valve-a power connector chu a loose em tih leh wire connector a loose em tih enfiah la, solenoid valve chu power supply-ah a inzawm em tih enfiah la, chu chu wire connector siamthat hmangin a chinfel theih ang.

3. Solenoid valve a tlak leh awm loh enfiah thin ang che. Inductance coil leh solenoid valve magnet inkar operating gap hi a tlem hle (0.008mm aia tlem). A tlangpuiin, hmun zau takah an dah a ni. Mechanical impurities a rawn luh emaw, lubricating oil a tlem lutuk emaw chuan a tlakbuak a awlsam hle. Double solenoid valve solution chu a chung lam round hole atang chuan steel wire hmangin a rawn pok lut thei a, chu chuan a rawn bounce leh thei a ni. Buaina chu fundamentally solve tur chuan solenoid valve chu thenfai a, valve core leh a sleeve te chu lakchhuah a, CCI4 hmanga tihfai a, valve core chu valve sleeve-ah a inthlak danglam thei ang bera kal tir tur a ni. Disassembly leh assembly lai hian device tinte installation sequence leh pawn lam wiring awmna tur bik ngaihtuah tur a ni a, chutiang chuan RE installation leh wiring dik tak a awlsam phah ang. Chutih rual chuan oil mist atomizer injection hole chu block a nih leh nih loh leh lubricating oil a tawk em tih pawh enfiah a ngai bawk.

4. Solenoid valve coil a chhiat chuan solenoid valve power wiring chu a inzawm lo thei a, multimeter hmangin a test thei bawk. Test result-ah chuan solenoid valve coil a chhiat thu a lang a nih chuan. A tlangpuiin, double solenoid valve a chhiat chhan ber chu inductance coil hi hygroscopic leh damp a nih vang a ni a, chu chuan insulation tha lo leh magnetic leakage a thlen a, chutah chuan inductance coil-a electric flow tam lutuk avanga fault a thlen thin vang a ni. Chuvangin, electronic valve chu hmun vawt takah a thawk thei tih chian a ngai a ni. Chu bakah, spring a harsat deuh chuan reaction force pawh a lian hle bawk. Coil turn zat a tlem lutuk chuan inductance coil chu sufficient suction dinhmun hnuaiah a chhe thei a ni. A tlangpuiin inductance coil thlakin a chinfel theih. Emergency a nih chuan inductance coil-a manual control switch chu "0" position atanga "1" position-ah normal operation hnuaiah dah theih a ni a, valve pawh hawn theih a ni bawk.


Inquiry thawn rawh .